active
Mishref Station
Client: Ministry of Public Works (MPW)
Equipment & Pump Overhaul Schedule
Total of 4 pumps registered for this project
| Tag / ID | Pump Details & Type | Electrical Specs | Hydraulic Specs | Mechanical / Bearings | Status | Certificate & Actions |
|---|---|---|---|---|---|---|
|
PUMP
Fresh water pumps (1,2,3)
|
Vertical Multistage In-Line Booster Pump
Vertical Multistage In-Line Booster Pump
Job: Stage Chamber Reconditioning, Impeller Stack Overhaul & Hydrostatic Pressure Test
Lowara • SV6002F55T
|
5.5 kW
415 V • 13.00 A
2900 RPM
|
Flow: 72 m³/hr
Head: 33 M
|
DE: 6308
NDE: 6308
Cartridge Balanced Mechanical Seal (EPDM)
|
TESTED / PASS | |
|
PUMP
SV9203/2F185T
|
Vertical Multistage In-Line Booster Pump
Vertical Multistage In-Line Booster Pump
Job: Stage Chamber Reconditioning, Impeller Stack Overhaul & Hydrostatic Pressure Test
LOWARA • SV9203/2F185T
|
18.5 kW (25 HP)
415 V • 30.30 A
2900 RPM
|
Flow: 120 m³/hr
Head: 120 m
|
DE: 6308
NDE: 6308
Cartridge Balanced Mechanical Seal (EPDM)
|
TESTED / PASS | |
|
PUMP
SV805F22T/A
|
Vertical Multistage In-Line Booster Pump
Vertical Multistage In-Line Booster Pump
Job: Stage Chamber Reconditioning, Impeller Stack Overhaul & Hydrostatic Pressure Test
Lowara • SV805F22T/A
|
2.2 kW (3 HP)
415 V • 4.60 A
2900 RPM
|
Flow: 14 m³/hr
Head: 62 m
|
DE: 6308
NDE: 6308
Cartridge Balanced Mechanical Seal (EPDM)
|
TESTED / PASS | |
|
PUMP
SV404F07T/2
|
Vertical Multistage In-Line Booster Pump
Vertical Multistage In-Line Booster Pump
Job: Stage Chamber Reconditioning, Impeller Stack Overhaul & Hydrostatic Pressure Test
LOWARA • SV404F07T/2
|
0.7 kW (1 HP)
415 V • 1.70 A
2900 RPM
|
Flow: 8 m³/hr
Head: 34 m
|
DE: 6203
NDE: 6202
Cartridge Balanced Mechanical Seal (EPDM)
|
TESTED / PASS |