Hydrotek Engineering Co.
Technical Services Division
ELECTRIC MOTOR OVERHAUL & TEST CERTIFICATE
Job / WO No:
HY-TSD-TR-2026-0634
Report No:
HY-TSD-TR-2026-0634
Date:
Result:
ACCEPTED
1. Equipment Details
| Project Details | Kabd Water Treatment Plant - Pump & Motor Repair overhauling (M/s. Contractor Co.) | ||
| Tag / Equipment ID | WEG-22kW | Location | Kabd Water Treatment Plant |
| Equipment Name | WEG motor (TEFC Squirrel Cage Induction Motor) | ||
| Motor Specs | 22kW | 415 V | 40.00 A | 2900 RPM RPM | ||
| Pump Specs | Model: WEG | ||
2. 1. ELECTRICAL & STATOR INSULATION TEST
| Test Parameter | Measured Value | Result |
|---|---|---|
| Stator Condition / Winding Status | Overhauled, Serviced & Tested OK | PASS |
| Winding Resistance (U1-U2, V1-V2, W1-W2 in Ohms) | U1–U2: 0.848 Ω | V1–V2: 0.832 Ω | W1–W2: 0.840 Ω | PASS |
| Insulation Resistance (500V DC) – Phase to Ground | U–G: 426.92 MΩ | V–G: 434.78 MΩ | W–G: 421.95 MΩ | PASS |
| Insulation Resistance (500V DC) – Phase to Phase | U–V: 473.54 MΩ | V–W: 478.82 MΩ | W–U: 464.23 MΩ | PASS |
3. 2. MECHANICAL SPECIFICATIONS & RENEWALS
| Component Checked | Replacement Details / Part No. | Result |
|---|---|---|
| Drive End (DE) Bearing Fitted | Part No: 6312 2Z/C3 • Brand: SKF (Replaced New) | PASS |
| Non-Drive End (NDE) Bearing Fitted | Part No: 6310 2Z/C3 • Brand: SKF (Replaced New) | PASS |
| Mechanical Seal / Seal Spec | Burgmann Cartridge Mechanical Seal • Static Leak Test: N/A | PASS |
4. 4. OPERATIONAL RUN TEST (NO-LOAD / FULL SYSTEM RUN)
| Test Parameter | Measured Value | Result |
|---|---|---|
| Running Current (A) | L1: 40 A | L2: 40.5 A | L3: 39.9 A | PASS |
| Bearing Temperature (°C) | DE: 48.5 °C | NDE: 43.2 °C (Normal) | PASS |
| Vibration Level | DE: 1.55 mm/s | NDE: 1.68 mm/s (Smooth) | PASS |
| Rotation & Seal Check | Rotation: Correct (CW) | Seal Leakage: Nil / None | PASS |
5. 5. SPECIALIZED WORKSHOP VERIFICATIONS
| Test Name | Standard / Criteria | Measured / Inspection | Result |
|---|---|---|---|
| Motor Insulation Test | 500W DC Meggar Test | No earth Leakage found | PASS |
| Painting Done | - | OK | PASS |
6. Sign-Off & Approvals
PREPARED BY:
ENG. JITHU THOMAS
Signature
Date: 07/05/2026
INSPECTED BY:
ASWATH KUMAR HOSDURG
Signature
Date: 07/05/2026
APPROVED BY:
ABU GEROGE
Signature
Date: 07/05/2026
Hydrotek Engineering Co. • Custom Equipment Overhaul & Test Certificate
REF: HY-TSD-TR-2026-0634 • PAGE 1 OF 1
Equipment Photographic Documentation & Overhaul Audit 0 photo(s)
Visual proof of equipment condition: Intake / Before Overhaul vs. Completed / After Overhaul.
1. Intake / Before Overhaul Condition
0 photosPhotographs taken upon arrival (nameplate, casing, impeller wear, physical damage).
No intake condition photographs uploaded yet.
2. Completed / Post-Overhaul Condition
0 photosPhotographs taken after reassembly, painting, rewinding, new bearings & test run.
No completion photographs uploaded yet.